Page 76 - RAYCOH_2026ENV3.0_Sensors
P. 76

Function description





                                                                Five output modes of E4/E5 switching value
                                                                                                       Target range
                                                                  1. Window  1
                                                                   NO                A11         A2
                                                                                     A
                                                                  2. Window  2
                                                                   NC
                                                                                     A2          A1
                                                                  3. single switch 1
                                                                   NO
                                                                                     A2
                                                                  4. single switch 2
                                                                   NC
                                                                                     A1
                                                                                target presence detection;
             Special Series - Economy                                 Target detected: switch closed; Target not detected: switch open





        Features                                                Two output modes of E2/E3 switching value
           Ÿ  Available in two specifications: with a 2-meter
                                                                                                     Target range
              cable and without a cable                         1. open mode
           Ÿ  M18 external thread mounting
                                                                                  A2             A1
           Ÿ  Easy installation


         Details
                                                                2. closed mode
           Ÿ  One NPN and one PNP switch output
                                                                                  A1             A2
           Ÿ  Standard operating voltage DC 10-30V
           Ÿ  temperature compensation



























                                                                           flat100×100mm        round rod  Ø  25mm
   71   72   73   74   75   76   77   78   79   80   81