UCC SENSOR                                                     mode Teach-in function   requirement


                                                                             condition

                                                                                    Place the target at the near switch point,connect
                                                                                    the TEACH-IN learning cable to the -UB setting A1
                                                                                    point until it is green and the indicator light blinks
                                                                                    more than 3 times, disconnect it.
                                                                               NO
                                                                                    Place  the  target  at  the  far  switch  point,  connect
                                                                         Windows mode  the TEACH-IN learning cable to the +UB setting A2
                                                                                    point until it is green and the indicator light blinks
                                                                                    more than 3 times, disconnect.
                                                                                     Place the target at the near switch point, connect
                                                                                     the TEACH-IN learning cable to the +UB setting A2
                                                                                    point until it is green and the indicator light blinks
                                                                                    more than 3 times, disconnect.
  Quick Selection
                                                                               NC
                                                                                    Place  the  target  at  the  far  switch  point,  connect
                                                                                    the TEACH-IN learning cable to the -UB setting A1
  Main Products                                                                     point until it is green and the indicator light blinks
                                                                                    more than 3 times, disconnect.
   Application           flat100×100mm       round rod  Ø  25mm                     Place  the  target  at  the  near  switch  point  and
                                                                                    connect  the  TEACH-IN  learning  cable  to  the  +UB
                                                                                    setting  A2  point  until  the  green  indicator  blinks
                                                                                    more than 3 times, disconnect.
   Connotation
                                                                               NO   Disconnect by covering the sensor with your hand
                                                                                    or  removing  all  objects  within  the  sensor's
                                                                                    detection  range  until  the  green  indicator  light
   Usage pattern                                                                    blinks  more  than  3  times.  Connect  the  TEACH-IN
                                                                         Switch Mode
                                                                                    learning cable to the -UB to set point A1.
   Features                                                                         Place the target at the near switch point, connect
                                                                                    the TEACH-IN learning cable to the -UB setting A1
                                                                                    point until the green indicator blinks more than 3
                                                                                    times, disconnect.
  Installation Notes
                                                                               NC
                                                                                    Disconnect  the  sensor  by  covering  it  with  your
                                                                                    hand  or  removing  all  objects  within  the  sensor's
   Accessores                                                                       detection range until the red indicator light blinks
                                                                                    more  than  3  times.  Connect  the  TEACH-IN
                                                                                    learning cable to +UB to set point A2.
   Unstable
   description                                                                      Cover  the  sensor  with  your  hand  or  remove  all
                                                                        Object presence   detection model  times  to  disconnect.  Set  point  A2  by  connecting
                                                                                    objects  within  the  sensor's  detection  range.  Set
                                                                                    A1 until the red indicator light blinks more than 3
   M12                                                                              TEACH-IN Learning Cable Connection-UB to point
                                                                                    the TEACH-IN learning cable to the +UB until the
   M18                                                                              red  indicator  light  blinks  more  than  3  times  to
                                                                                    disconnect.

   M30                                                                 Factory settings
                                                                       A1 : Blind zone (minimum working range)
                                                                       A2 : Maximum range