Page 27 - RAYCOH_2026ENV3.0_Sensors
P. 27
Output Method and Reference Graph
Two output modes of E2/E3 switching value
Target range
1. open mode
A2 A1
2. closed mode
A1 A2
Five output modes of E4/E5 switching value
Target range
1. Window 1
NO A A11 A2
M18 CYLINDRICAL
2. Window 2
NC
A2 A1
3. single switch 1
Feature
NO
Ÿ M18 Mounting Thread Sleeve A2
Ÿ Easy to install
4. single switch 2
NC
A1
Details target presence detection;
Ÿ 1 npn or pnp switching output Target detected: switch closed; Target not detected: switch open
Ÿ 2 npn or pnp switching outputs
Ÿ Analogue voltage output 0-10V or analogue current
output 4-20mA E6/E7 dual switching 3 output modes
Tip: Connect the learning wire to the negative terminal to
Ÿ Latest IO-Link outputs, RS485 modbus-rtu outputs
set A1; connect it to the positive terminal to set A2.
Ÿ Detection distance learning function via grey line
1. A1 A2
Ÿ Standard operating voltage DC 10-30V
Ÿ temperature compensation Switch output 1 Target range
black signal wire
Switch output 2
white signal wire
A2 A1
Switch output 1 Target range
white signal wire
Switch output 2
black signal wire
Switch A1 Output 1 ; Detect that existence of an object.
Black wire (NC mode)
Switch A2 Output 2 ; Detect that existence of an object.
White wire (NO mode)
Switch A1 &A2 Double output; Detect that existence of an object
25