Page 29 - RAYCOH_2026ENV3.0_Sensors
P. 29

UB300                                               Teach-in function


                     Y(mm)                                    mode  condition           requirement
                    75
                                                                            Place the target at the near switch point,connect
                    50                                                      the TEACH-IN learning cable to the -UB setting A1   M18 CYLINDRICAL
                                                                            point until it is green and the indicator light blinks
                                                                            more than 3 times, disconnect it.
                                                                       NO
                                                                            Place  the  target  at  the  far  switch  point,  connect
                                                                            the TEACH-IN learning cable to the +UB setting A2
                   -50                                                      point until it is green and the indicator light blinks
                   -75                                                      more than 3 times, disconnect.
                     0  50 100 150 200 250 300 350 400 450 500  Windows mode  Place the target at the near switch point, connect
                                           X(mm)                            the TEACH-IN learning cable to the +UB setting A2
                                                                            point until it is green and the indicator light blinks
                                                                            more than 3 times, disconnect.   Quick Selection
                 flat100×100mm        round rod  Ø  25mm               NC
                                                                            Place  the  target  at  the  far  switch  point,  connect
                                                                            the TEACH-IN learning cable to the -UB setting A1
                                                                            point until it is green and the indicator light blinks   Main Products
                                                                            more than 3 times, disconnect.
             UB500
                                                                            Place  the  target  at  the  near  switch  point  and   Application
                                                                            connect  the  TEACH-IN  learning  cable  to  the  +UB
                                                                            setting  A2  point  until  the  green  indicator  blinks
                     Y(mm)                                                  more than 3 times, disconnect.
                    200                                                                                      Connotation
                                                                       NO   Disconnect by covering the sensor with your hand
                    150                                                     or  removing  all  objects  within  the  sensor's
                    100                                                     detection  range  until  the  green  indicator  light   Usage pattern
                                                                            blinks  more  than  3  times.  Connect  the  TEACH-IN
                                                                Switch Mode  Place the target at the near switch point, connect   Features
                     50                                                     learning cable to the -UB to set point A1.
                     50                                                     the TEACH-IN learning cable to the -UB setting A1
                    100                                                     point until the green indicator blinks more than 3
                                                                            times, disconnect.               Installation Notes
                    150                                                NC
                                                                            Disconnect  the  sensor  by  covering  it  with  your
                    200                                                     hand  or  removing  all  objects  within  the  sensor's
                      0    200  400   600  800  1000
                                                                            detection range until the red indicator light blinks   Accessores
                                          X(mm)                             more  than  3  times.  Connect  the  TEACH-IN
                                                                            learning cable to +UB to set point A2.
                                                                                                             Unstable
                 flat100×100mm        round rod  Ø  25mm                    Cover  the  sensor  with  your  hand  or  remove  all   description
                                                                Object presence   detection model  TEACH-IN Learning Cable Connection-UB to point   M12
                                                                            objects  within  the  sensor's  detection  range.  Set
                                                                            A1 until the red indicator light blinks more than 3
                                                                            times  to  disconnect.  Set  point  A2  by  connecting
             UB1000                                                         the TEACH-IN learning cable to the +UB until the   M18
                                                                            red  indicator  light  blinks  more  than  3  times  to

                      (Y mm )                                               disconnect.
                    400                                                                                      M30
                    300
                    200
                                                                                                             UDA
                    100

                                                                 Teach-in function                           UCC
                   -100
                   -200
                   -300                                        Sensors of different models or the same model can   UDB
                                                             realize asynchronous function or synchronous function,
                   -400
                          200  400  600  800  1000  1500     which needs to be realized by synchronous controller.
                                           X mm(  )                                                          UR

                 flat100×100mm        round rod  Ø  25mm                                                     Special Series


                                                                                                             Square Series


                                                                                                             Wireless Series


                                                                                                    27       UGT
   24   25   26   27   28   29   30   31   32   33   34