UB300                                              Teach-in function


                   Y(mm)                                    mode   condition           requirement
                  75
                                                                           Place the target at the near switch point,connect
                  50                                                       the TEACH-IN learning cable to the -UB setting A1   M18 BENDS
                                                                           point until it is green and the indicator light blinks
                                                                           more than 3 times, disconnect it.
                                                                      NO
                                                                           Place  the  target  at  the  far  switch  point,  connect
                                                                           the TEACH-IN learning cable to the +UB setting A2
                 -50                                                       point until it is green and the indicator light blinks
                                                                           more than 3 times, disconnect.
                 -75
                    0  50 100 150 200 250 300 350 400 450 500  Windows mode  Place the target at the near switch point, connect
                                           X(mm)                           the TEACH-IN learning cable to the +UB setting A2
                                                                           point until it is green and the indicator light blinks
                                                                           more than 3 times, disconnect.    Quick Selection
                 flat100×100mm       round rod  Ø  25mm               NC
                                                                           Place  the  target  at  the  far  switch  point,  connect
                                                                           the TEACH-IN learning cable to the -UB setting A1
                                                                           point until it is green and the indicator light blinks   Main Products
                                                                           more than 3 times, disconnect.
            UB500
                                                                           Place  the  target  at  the  near  switch  point  and   Application
                                                                           connect  the  TEACH-IN  learning  cable  to  the  +UB
                                                                           setting  A2  point  until  the  green  indicator  blinks
                       Y(mm)                                               more than 3 times, disconnect.
                   200                                                                                       Connotation
                                                                      NO   Disconnect by covering the sensor with your hand
                   150                                                     or  removing  all  objects  within  the  sensor's
                   100                                                     detection  range  until  the  green  indicator  light   Usage pattern
                                                                           blinks  more  than  3  times.  Connect  the  TEACH-IN
                                                               Switch Mode  Place the target at the near switch point, connect   Features
                   50                                                      learning cable to the -UB to set point A1.
                   50                                                      the TEACH-IN learning cable to the -UB setting A1
                   100                                                     point until the green indicator blinks more than 3
                                                                           times, disconnect.                Installation Notes
                   150                                                NC
                                                                           Disconnect  the  sensor  by  covering  it  with  your
                   200
                     0    200  400   600  800  1000                        hand  or  removing  all  objects  within  the  sensor's
                                                                           detection range until the red indicator light blinks   Accessores
                                           X(mm)                           more  than  3  times.  Connect  the  TEACH-IN
                                                                           learning cable to +UB to set point A2.
                                                                                                             Unstable
                 flat100×100mm       round rod  Ø  25mm                    Cover  the  sensor  with  your  hand  or  remove  all   description
                                                               Object presence   detection model  TEACH-IN Learning Cable Connection-UB to point   M12
                                                                           objects  within  the  sensor's  detection  range.  Set
                                                                           A1 until the red indicator light blinks more than 3
                                                                           times  to  disconnect.  Set  point  A2  by  connecting
            UB1000                                                         the TEACH-IN learning cable to the +UB until the   M18
                                                                           red  indicator  light  blinks  more  than  3  times  to

                   (Y mm )                                                 disconnect.
                   400                                                                                       M30
                                                              Factory settings
                   300
                                                              A1 : Blind zone (minimum working range)
                   200                                        A2 : Maximum range
                                                                                                             UDA
                   100

                   100                                                                                       UCC
                   200                                          Teach-in function
                   300                                                                                       UDB
                   400                                         Sensors of different models or the same model can
                     0   200  400  600  800 1000  1500
                                        X mm(  )            realize asynchronous function or synchronous function,   UR
                                                            which needs to be realized by synchronous controller.
                 flat100×100mm       round rod  Ø  25mm                                                      Special Series


                                                                                                             Square Series


                                                                                                             Wireless Series


                                                                                                    37       UGT